DE EN TR open the System Schröders - door
Technische Zeichnung ESN1

Burglar resistance door

System Schröders ESN-1

Single-leaf burglar resistance steel door

Burglar resistance

RC4 - classification report no. 22-5/15.123, PIV-Velbert
RC3 - classification report no. 22-4/15.123, PIV-Velbert
RC2 - classification report no. 45-47/22.122, PIV-Velbert
RC1 - classification report no.. 45-47/22.122, PIV-Velbert

according to DIN EN 1627 ff

Acoustic performance
(optional)
up to RW (C;Ctr) = 53 (-1;-5) dB*
according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717-1 (e.g. "ESN-1")
* depending on size, see assessment SEII-16-0211-Hrd, TÜV Nord (de)
 
Thermal transmittance
(optional)

UD-Wert ≥ 1.3 W/(m²K) according to EN ISO 10077-1

Behaviour between different climates according to EN 12219 (deflection) class 2 (d + e)
Airtightness
(optional)
according to EN 12207, up to class 4
Resistance to wind load
(optional)
according to EN 12210, up to class C5
Watertightness
(optional)
according to EN 12208, up to class 8A
Ability to release
(optional)
 
Resistance to positive and negative pressure
(optional)
up to 5,000 Pa
Installation in outer walls
(optional)
CE-Zeichen marked according to EN 14351-1
 
Technical data
Dimensions
standard dimensions
width from 625 mm to 1,500 mm
heigth from 500 mm to 3,000 mm
 
Door leaf leaf thickness 68 / 70 mm - smooth, double-walled
plate thickness 1.5 mm to 2.0 mm
mineral wool filling (other fillings on request)
 
Door frame loor frame "ZNG"
  • elastic rubber seal (optonal)
corner frame
  • optional closed frame
Glazing
(optional)
glass dimensions variable
minimum frieze width: 130 mm
  • optional cross bars
RC4: glazing according to EN356 min. P6B
RC3: glazing according to EN356 min. P5A
Glazing beads with concealed screws
Floor seal
  • optional retractable floor seal or patented sliding seal
Lock options
RC4: Three-point lock
  - (optional NEMEF, BMH, HZ-Lock, Fliether, Dorma, eff eff)
  - gecuring pins
 
  - for panic lock with full-surface drilling protection
 
RC3: simple locking with single-latch bolt lock min. DIN 18251 class 3
 
  • optional panic lock (not with glazing)
  from door height > 2,500 mm
  - three-point lock
(optional NEMEF, BMH, HZ-Lock, Fliether, Dorma, effeff)
  - dogbolts
 
Rebate protection rebate protection through ESP safety profile (patent-protected)
 
Hardware / fittings
  • optional any appropriate lever handle set
  • optional panic push-bar
  • RC4 performance: Security fitting 18257 ES3
  • RC3 performance: Security fitting 18257 ES2
  • RC1 or RC2 performance: Security fitting 18257 ES1

door closer according to EN 1154 (optional Bodentürschließer)

2/3-part KO door hinges
with patented easy-running bearings as easy running doors
or with ball bearing rings

optional hinge with 3D adjustability

for smaller doors, optionally with spring hinge

Installation
  • in masonry
  • in concrete
  • in aereated concrete
  • in steel frame
  • optional blunt mount
Options ­additional safety equipment possible
  • (­magnetic contact, bolt contact, electric door opener)
  • with door closers
thick rebate design
stainless steel finish
further version on request