System Schröders steel doors
Tested and classified
|
|||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
optional all doors with glazing
|
|||||||||||||||||
ModulSystem Schröders | Fire resistance | Smoke control
EN 1634-3 |
Burglar resistance
EN 1627 ff |
Acoustic performance
EN ISO 10140-1 EN ISO 10140-2 EN ISO 717-1 |
Airtightness
wind load watertightness |
Positive and negative pressure EN 12211 |
|||||||||||
Designation | Number of
leaves |
Dimensions*
width x height (in mm) |
FLAT | Resistance | Designation | Resistance-
class |
dB | Class | |||||||||
SN-1
Acoustic performance |
1 |
|
✓ | - | - | - | up to
RW(C;Ctr) = 53 (-1;-5) dB |
Air up to 4
Wind up to C5 Water up to 8A |
up to 5,000 Pa | ||||||||
SN-2
Acoustic performance |
2 |
|
✓ | - | - | - |
up to
RW(C;Ctr) = 48 (-1;-5) dB |
Air up to 3
Wind up to C4 Water up to 3A |
up to 3,800 Pa | ||||||||
* bigger dimensions on request | |||||||||||||||||
Further System Schröders door types with optional acoustic performance | |||||||||||||||||
optional all doors with glazing
|
|||||||||||||||||
ModulSystem Schröders | Fire resistance | Smoke control
EN 1634-3 |
Burglar resistance
EN 1627 ff |
Acoustic performance
EN ISO 10140-1 EN ISO 10140-2 EN ISO 717-1 |
Airtightness
wind load watertightness |
Positive and negative pressure EN 12211 |
|||||||||||
Designation | Number of
leaves |
Dimensions*
width x height (in mm) |
FLAT | Resistance | Designation | Resistance-
class |
dB | Class | |||||||||
TSN-1 EI230
Fire resistance class EI2 acc. to EN 16034 CE marked |
1 |
|
✓ | EI230-Sa4-C5 | S200 | RC4
RC3 RC2 RC1 |
to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
TSN-2 EI230
Fire resistance class EI2 acc. to EN 16034 CE marked |
2 |
|
✓ | EI230-Sa4-C5 | S200 | RC4
RC3 RC2 RC1 |
up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
TSN-11 EI290
Fire resistance class EI2 acc. to EN 16034 CE marked |
1 |
|
✓ | EI290-Sa4-C5 | S200 | RC4
RC3 RC2 RC1 |
up to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
TSN-12 EI290
Fire resistance class EI2 acc. to EN 16034 CE marked |
2 |
|
✓ | EI290-Sa4-C5 | S200 | RC4
RC3 RC2 RC1 |
up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
ESN-1
Burglar resistance |
1 |
|
✓ | - | - | RC4
RC3 RC2 RC1 |
up to
RW(C;Ctr) = 53 (-1;-5) dB |
Air up to 4
Wind up to C5 Water up to 8A |
up to 5,000 Pa | ||||||||
ESN-2
Burglar resistance |
2 |
|
✓ | - | - | RC4
RC3 RC2 RC1 |
up to
RW(C;Ctr) = 48 (-1;-5) dB |
Air up to 3
Wind up to C4 Water up to 3A |
up to 3,800 Pa | ||||||||
* bigger dimensions on request |