DE EN TR open the System Schröders - door
Technische Zeichnung TSN-1-CE

Fire resistance doorset according to European standard EI230

System Schröders TSN-1 CE

Single-leaf fire resistant steel doorset / flap EI230-Sa4-C5-according to EN 16034

CE-label labeled

Fire resistance

EI230-Sa4 tested according to EN 1634-1

  • tested as a gate according to DIN EN 13241-1
  • tested as an external door according to DIN EN 14351-1
Thermal transmittance

UD-value ≥ 1.3 W/(m²K) according to EN ISO 10077-1

Combinable with additional performance characteristics:

Smoke control
(optional)

S200 tested according to EN 1634-3

Burglar resistance
(optional)

RC4 - classification report no. 22-5/15.123, PIV-Velbert
RC3 - classification report no. 22-4/15.123, PIV-Velbert
RC2 - classification report no. 45-47/22.122, PIV-Velbert
RC1 - classification report no.. 45-47/22.122, PIV-Velbert

according to DIN EN 1627 ff

Acoustic performance
(optional)

up to RW (C;Ctr) = 53 (-1;-5) dB

according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717

proof of airborne sound insulation for security doors
(measurement reports, test reports, expert opinions)

Air tightness
(optional)

up to class 4 according to EN 12207 (up to 600 Pa)

expert opinion no. 11-000082-PR01
Resistance to wind load
(optional)

up to class C5 (up to 2,000 Pa) according to EN 12210

expert opinion no. 11-000082-PR01
Watertightness
(optional)

up to class 8A according to EN 12208

expert opinion no. 11-000082-PR01
Resistance to positive and negative pressure
(optional)

up to 5.000 Pa according to DIN EN 12211

expert opinion no. 16-003037-PR01
Behaviour between different climates
(optional)

class 2 (d + e) according to EN 12219 (deflection)

Ability to release
(optional)

according to DIN EN 16034
hold-open device according to DIN EN 14637

according to DIN EN 14351-1
proven for doors in escape and rescue routes

Flush with surface
(optional)

flush-mounted design FLAT

Explosion protection
(optional)
Logo ATEX For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for System Schröders hinged doors (in German language) (PDF)
Technical data
Dimensions
(shell dimension)
width from 525 mm up to 2,300 mm
height from 500 mm up to 4,600 mm
Dimensions flap
(shell dimension)
width from 525 mm up to 1,500 mm
height from 500 mm up to 3,000 mm
Door leaf

leaf thickness 68 mm to 69 mm - smooth double-walled
plate thickness 1.0 mm to 1.5 mm

  • thin rebate design
    • optional thick rebate design
    • insulating insert
      • optional insulation inlet full-face glued and pressed with cover plate
        thus particularly plane and smooth door leaf
Frame
  • frame-system "ZNG" with flush clipped in Thelesol® fire protection strips
  • or
  • frame-system "ZG"
  • (see installation variants)
  • corner frame
  • optional enclosing frame
  • optional block frame

with elastic rubber seal
(seal type depending on performance characteristic)

Floor seal

required for smoke control, acoustic performance, air tightness

  • optional lowerable floor seal or
  • sliding seal
Glazing
(optional)

glass dimensions and -form variable
(rectangular glass inset max. 980 mm x 2,180 mm)

minimum frieze width: 130 mm

  • optional with intermediate glass inset bars
  • optional with port-hole (ø approx. 450 mm clear view)

glass inset bars with concealed screw connection (for rectangular glass inset)

Hinges

2/3-part KO door hinges
with patented easy-running bearings as easy running doors
or with ball bearing spacers

  • optional door hinge with 3D adjustment
Fittings
  • optional any approved handle set according to EN1906 resp. EN179
  • optional panic bar handle or push bar according to EN 1125
Locking

single locking according to EN 12209, depending on version multi-point locking
profile cylinder prepared (cylinder on-site)
dogbolts

  • optional panic locking according to EN179 resp. EN 1125
Self-closing

door closer according to DIN EN 1154

  • optional spring hinge for smaller doors / flaps
Installation
  • in masonry(thk ≥ 115 mm)
  • in concrete(thk ≥ 100 mm)
  • in aerated concrete(thk ≥ 150 mm)
  • in flexible walls min. F30(thk ≥ 100 mm)
  • in encased steel columns min. F30(thk ≥ 100 mm)
  • optional blunt installation in soffit
  • optional installation on the wall plate
  • approved for installation at great heights (installation not at floor level: height on one or both sides > 500 mm above ground level - e.g. as manhole door/flap) with lower fire and smoke seal - also thresholdless
Label

CE-label labeled for firedoors according to EN 16034

Optional
  • additional security devices possible
    (magnetic contact, bolt contact, e-opener...)
  • door in stainless steel

The specifications refer to the usual equipment variants. Individual equipment may be required when combining different performance characteristics.

The licensed System Schröders manufacturers will be happy to advise you on planning your requirements.