technical drawing EIS-1

Fire resistance door class EI

System Schröders EIS-11

Single-leaf fire resistance door EI2 120 / E 120 / EW 60 (Sa)

Fire resistance EI2 120 / E 120 / EW 60
tested in accordance with EN 1634-1
classification report WFRC 360408 according to EN 13501-2
Smoke protection
(optional)
Sa tested according to EN 1634-3
classification report WFRC 360408 according to EN 13501-2  
Thermal transmittance
(optional)

UD-Wert ≥ 2.7 W/(m²K) according to EN ISO 10077-1

Airtightness
(optional)
according to EN 12207, up to class 4
Resistance to wind load
(optional)
according to EN 12210, up to class C5
Watertightness
(optional)
according to EN 12208, up to class 8A
Ability to release
(optional)
 
Resistance to positive and negative pressure
(optional)
up to 5,000 Pa
Technical data
Dimensions
Standard dimensions
width from 500 mm to 1,400 mm
heigth from 750 mm to 2,650 mm
Door leaf Leaf thickness 68 / 69 mm - smooth, double-walled, galvanized or optional stainless steel
plate thickness up to 1.5 mm
  • insulation inlay covered with a fully adhering cover sheet, to result in a super smooth and flat door leaf
  • "Thelesol­120" ­fire protection strip on the door leaf edges
Door frame Door frames „System Schröders“
(see installation variants)

optional with elastic smoke protection seal
corner frame profile, three­, or optional four sided wrap­around frame option
Floor seal Required for smoke protection, increased air tightness, driving rain tightness
  • four-sided frame seal
Lock options Latch lock according to EN 12209
profile cylinder prefab (cylinder on-site)
  • optional panic lock
  • optional multiple interock
securing bolt
Hardware / fittings
  • Optional any appropriate lever handle set
  • optional panic push-bar

door closer according to EN 1154

2/3-part KO door hinges
with patented easy-running bearings as easy running doors
or with ball bearing rings

optional hinge with 3D adjustability

for smaller doors, optional with spring hinge

  • optional power drive door opener according to EN 1155
Installation
- in masonry
- in concrete
  • optional blunt mount between the recesses
Options
  • ­additional safety equipment possible
    (magnetic contact, bolt contact, electric door opener)
  • with door closers
  • thick rebate design (development in progress)
  • stainless steel
  • protective kick plates ≤ 1.5 mm on the door panel
  • door panel covered with laminates or genuine wood veneer ≤ 1.5 mm